Leave Your Message

Banatton 3KVA 220V online UPS offline UPS backup uninterruptible power supply

Brand: Banatton

Place of origin: China

Type: offline UPS

Model Number: 500~3000VA

Display: LCD or LED

Phase: Single Phase

Waveform: pure sine wave

Capacity: 500VA 850VA 1000VA 1500VA 2000VA 3000VA

Protection: short-circuit, over voltages, reverse connection protection

OEM/ODM: Yes

Supply Ability: 50000 Piece/Pieces per Month

Packaging: Carton box package or as you requested

    Offline UPS (1).jpg

    Feature:

     

    Title: Understand the difference between 3KVA 220V online and offline UPS

     In today's digital age, uninterruptible power supply (UPS) systems are critical to businesses and individuals alike.  When choosing a UPS that suits your needs, it's important to understand the differences between the various types and sizes.  In this blog, we will delve into the differences between 3KVA 220V online and offline UPS systems.

     First, let’s understand what the term “3KVA” means.  KVA stands for kilovolt ampere and is a unit of electricity.  3KVA UPS is capable of delivering 3 kV amps of power and is suitable for powering critical equipment and installations.

     In terms of input voltage, a 220V UPS is designed to operate on a 220 volt input.  This is a common voltage standard in many regions, and it is important to ensure that the UPS matches the input voltage of the electrical system to which it is connected.

     Now, let's differentiate between online and offline UPS systems.  Online UPS provide continuous power to connected devices by continuously converting AC power to DC power and back again.  This ensures a seamless transition during power outages, making it ideal for sensitive equipment such as servers and data centers.

     On the other hand, an offline UPS (also known as a backup UPS) switches to battery power only when a power outage is detected.  This brief transition may cause a brief interruption in power supply, which may not be suitable for equipment that requires continuous uninterrupted power.

     When choosing between a 3KVA 220V online and offline UPS, it is important to consider the specific requirements of the equipment to be powered.  If you need to provide continuous, seamless power to critical systems, an online UPS is the ideal choice.  However, if your equipment can withstand brief power outages, an offline UPS may be sufficient.

     In summary, understanding the differences between 3KVA 220V online and offline UPS systems is crucial to making an informed decision.  By considering the specific power requirements and the nature of the connected equipment, you can select the most suitable UPS to ensure uninterrupted power and protect your valuable equipment from unexpected power outages.

     

    Offline UPS (8).jpg

    Offline UPS (6).jpg

     

    Technical Parameters:

     

    Technical Parameters

    SPECIFICATIONS 

    AL-500

    AL-1000

    AL-2000

    Capacity 

    500VA/300W

    1000VA/600W

    2000VA/1200W

    INPUT

     

    Voltage 

    220/230VAC

    Voltage range 

    145-275VAC

    Frequency range 

    50Hz or 60Hz(auto-sensing)

    OUTPUT

     

    Output voltage 

    220/230 VAC

    AC voltage regulation 

    ± 10%

    Frequency range(batt. mode) 

    50 HZ or 60 Hz ± 10%

    Transfer time 转换时间

    Typical 6-10 ms

    Waveform(batt. mode) 

    Simulated sine wave 

    BATTERY

     

    Battery voltage 

    12 VDC

    24 VDC

    24 VDC

    Float voltage 

    13.7VDC ± 0.5 VDC

    27.4VDC ± 1VDC

    27.4VDC ± 1VDC

    Charge current(Max.) 

    5A

    5A

    5A

    PROTECTION

     

    Full protection 

    Short circuit, Over load, Battery low voltage protection 

    Optional USB or RS232 communication port or SNMP 

    Optional 

    RJ11/RJ45 port RJ11/RJ45 

    Optional

    INDICATORS

     

    Line mode 

    Green lighting

    Battery mode 

    Red lighting 

    Battery charge mode 

    Yellow lighting 

    ALARM

     

    Battery mode 

    Sounding every 10 seconds 

    Low battery 

    Sounding every second 

    Overload 

    Sounding every 0.5 second 

    Fault 

    Continuously sounding 

    ENVIRONMENT

     

    Humidity 

    0-90% RH @ 0-40℃ (Non-condensing) 0-90%

    Noise level 

    Less than 45dB 

    Dimension(mm)

    330x100x150

    365x140x165

    395x145x210

    N.W.(kg) 

    3.5

    7

    8.5

     

    We can apply the following adapters:

     

    Offline UPS (7).jpg

     

    Our services:

     

    1. OEM&ODM services acceptable.

    2. Lots of cooperated agent for shipping by sea or by air.

    3. 1year warranty, if it is quality problem, we will provide the parts for free.

     

    Applications:

     

    Offline UPS (4).jpg

     

    IT infrastructure: small server and workstation, router and switch, monitoring equipment; Automation system: ATM, TVM, SCADA, Railway and Metro signal system; Office and Business Equipment: PC, Printer, Scanner, POS, Telephones and Fax.

     

    Factory Production Line:

     

    Offline UPS (5).jpg

     

    Offline UPS (2).jpg

     

    Packaging:

     

    Cold start function, Output modified sine wave, Mains restart function, Automatic charge in off-mode。

    Different AC input power cables, different type outlets. Meet every countries.

    Welcome customize order with logo design or outlook design. Please contact our sales for more details.