Banatton UPS Uninterruptible power supply 60KVA three phase 220V for IT date room
Description
Brand: Banatton
Place of origin: China
Type: online UPS
Model Number: BNT9300-M 20~300KVA
Phase: Three Phase
Waveform: Pure sine wave
Transfer time: 0ms
Power factor: 0.9
Capacity: 20KVA-300KVA
Protection: short-circuit, over voltages, reverse connection protection
OEM/ODM: Yes
Supply Ability: 5000 Piece/Pieces per Month
Packaging: Carton or wooden box package or as you requested
Features
Title: The importance of online UPS for uninterrupted power supply
In today's digital age, uninterruptible power supplies (UPS) are critical for businesses and individuals alike. With increasing reliance on electronic devices and the internet, any power outage can cause significant inconvenience and financial loss. This is where online UPS comes into play, providing a reliable solution that ensures uninterrupted power supply.
Online UPS, also known as double-conversion UPS, are designed to provide continuous power protection by converting AC input power to DC power and then back to AC power. This process ensures a stable and clean power supply, free from fluctuations and disturbances. Unlike offline UPS, which require some switching time during a power outage, online UPS can seamlessly transition to battery power without any interruption, making it ideal for critical applications.
One of the main advantages of an online UPS is its ability to protect sensitive electronic equipment from power disturbances. Whether it’s a sudden voltage spike, frequency change or a complete power outage, an online UPS ensures that connected equipment continues to operate without any interruption. This is especially important for businesses that rely on the continued operation of IT infrastructure such as data centers, server rooms and communications networks.
In addition, online UPS provides reliable backup power during emergencies, allowing users to safely shut down equipment and prevent data loss or hardware damage. This is especially valuable in areas with frequent power outages or unstable grids.
In addition to technical capabilities, online UPS also provides powerful and reliable power protection solutions to give users peace of mind. Whether it's a home office setup, a small business or a large enterprise, having a reliable online UPS system ensures operations can continue without interruption, ultimately helping to increase productivity and customer satisfaction.
In summary, the importance of an online UPS for uninterrupted power supply cannot be overstated. Its ability to provide continuous, clean power, protect sensitive equipment and provide you with peace of mind makes it an important investment for anyone who relies on a stable power source. By choosing an online UPS, individuals and businesses can reduce the risks associated with power outages and ensure seamless operation of their electronic equipment.
Little Hint
1. In the warranty period the machine has a problem, please contact the sales staff, we will be responsible for customer service.
2. Exceed the warranty period, improper operation and man-made damage, we will still give help and support, we will provide spare parts at a cost price.
3. According to the customer's needs, we can provide unconventional, but the cost may be slightly higher than the traditional machine.
Applications
Data processing center, The host system, Computer servers, Medical, Traffic, Electricity, IT, Industrial and other industries.
Factory Production Line
Packaging
MODEL |
BNT990-M |
BNT9150/180-M |
BNT9300-M |
|
Rated Capacity |
Cabinet Capacity |
20-90kVA / 20-90kW |
25-150kVA / 25-150kW 30-180kVA / 30-180kW |
30-300kVA / 30-300kW |
One Ppwer Module Capacity |
20kVA /20kW, 25kVA /25kW,30kVA /30kW |
|||
MAX. Power Module NO. |
3 |
5/6 |
10 |
|
INPUT |
||||
Main Input |
Nominal Voltage(Vac) |
380/400/415 |
||
Voltage Range(Vac) |
138~485Vac;305~485Vac load,138~305Vac load |
|||
Phase |
3-phase in / 3-phase out |
|||
Nominal Frequency(Hz) |
40-70 |
|||
Power Factor |
≥0.99 |
|||
Harmonic Distortion (THDi) |
≤3% (100% load) |
|||
Bypass Input |
Nominal Voltage(Vac) |
380/400/415 |
||
Voltage Range(Vac) |
220 Vac:25%(+10%,+15%,+20%) |
|||
230 Vac:20%(+10%,+15%) | ||||
240 Vac:15%(+10%);-45%(-10%,-20%,-30%) | ||||
Phase |
3-phase in / 3-phase out |
|||
Power Walking In |
YES |
|||
Bypass Back Irrigation |
YES |
|||
Generator Access |
YES |
|||
OUTPUT |
||||
Voltage(Vac) |
380/400/415±1% |
|||
Power factor |
1 |
|||
Frequency(Hz) |
AC Mode |
±1%/±2%/±4%/±5%/±10% |
||
Battery Mode |
(50/60±0.1%)Hz |
|||
Waveform |
Pure Sinewave |
|||
Admissible Crest Factor |
3:01 |
|||
Harmonic Distortion(THDV) |
≤2% (100%Linear Load);≤3% (100%Non-linear Load) |
|||
Transfer Time(ms) |
0 |
|||
Efficiency(%) |
95.50% |
|||
Overload Capability |
1 hour for 110%, 10 mins for 125%,1 min for 150%, 200ms for >150% |
|||
BATTERY |
||||
Maximum Charging Current(A) |
18 |
|||
Nominal Voltage |
±180V/±192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc |
|||
(30/32/34/36/38/40/42/44/46/48/50 pcs) | ||||
ENVIRONMENT |
||||
Operating Temperature |
0℃~40℃ |
|||
Storage Temperature |
-25℃~55℃ |
|||
Relative Humidity |
0~95% |
|||
Altitude |
< 1500m |
|||
Noise Level(dB) |
<58dB |
<61dB |
<68dB |
|
PHYSICAL |
||||
Dimension (D x W x H) mm |
UPS Cabinet |
600×850×1350 |
600×850×1350 600×850×1550 |
600×850×2000 |
Module |
440×620×86 |
|||
Net Weight(kg) |
UPS Cabinet |
140 |
155/170 |
290 |
Module |
21 |