Desain Khusus untuk Sunpal Fase Tunggal Off Grid Storage Inverter 3000W UPS 220V dengan Charger Baterai
Niat kita kudu nepaki konsumen kita kanthi nawakake panyedhiya emas, rega sing unggul lan kualitas sing unggul kanggo Desain Khusus kanggo Sunpal Single Phase off Grid Storage Inverter 3000W UPS 220V karo Pangisi Daya Baterei, Sugeng rawuh kanggo kerja sama lan netepake karo kita! kita bakal terus nawakake barang dagangan kanthi kualitas premium lan biaya sing kompetitif.
Niat kita kudu nepaki konsumen kanthi nawakake panyedhiya emas, rega sing unggul lan kualitas sing unggulChina Storage Inverter lan UPS 220V Inverter karo Charger Baterei , Kita wis menang reputasi apik antarane klien jaban rangkah lan domestik. Adhering to tenet Manajemen "kredit oriented, customer pisanan, efficiency dhuwur lan layanan diwasa", kita warmly welcome kanca saka kabeh mlaku gesang kanggo kerjo bareng karo kita.
Fitur
Petunjuk Cilik
1. Ing wektu garansi mesin duwe masalah, hubungi staf sales, kita bakal tanggung jawab kanggo layanan pelanggan.
2. Ngluwihi wektu babar pisan, operasi sing ora bener lan karusakan buatan manungsa, kita isih bakal menehi bantuan lan dhukungan, kita bakal nyedhiyakake spare parts kanthi rega biaya.
3. Miturut kabutuhan pelanggan, kita bisa nyedhiyakake ora konvensional, nanging biaya bisa rada luwih dhuwur tinimbang mesin tradisional.
Aplikasi
Pusat pangolahan data, Sistem host, Server Komputer, Medis, Lalu Lintas, Listrik, IT, Industri lan industri liyane.
Lini Produksi Pabrik
Kemasan
Niat kita kudu nepaki konsumen kita kanthi nawakake panyedhiya emas, rega sing unggul lan kualitas sing unggul kanggo Desain Khusus kanggo Sunpal Single Phase off Grid Storage Inverter 3000W UPS 220V karo Pangisi Daya Baterei, Sugeng rawuh kanggo kerja sama lan netepake karo kita! kita bakal terus nawakake barang dagangan kanthi kualitas premium lan biaya sing kompetitif.
Desain khusus kanggoChina Storage Inverter lan UPS 220V Inverter karo Charger Baterei , Kita wis menang reputasi apik antarane klien jaban rangkah lan domestik. Adhering to tenet Manajemen "kredit oriented, customer pisanan, efficiency dhuwur lan layanan diwasa", kita warmly welcome kanca saka kabeh mlaku gesang kanggo kerjo bareng karo kita.
MODEL | BNT990-M | BNT9150/180-M | BNT9300-M | |
Kapasitas Rated | Kapasitas Kabinet | 20-90kVA / 20-90kW | 25-150kVA / 25-150kW 30-180kVA / 30-180kW | 30-300kVA / 30-300kW |
Siji Kapasitas Modul Ppwer | 20kVA / 20kW, 25kVA / 25kW, 30kVA / 30kW | |||
MAX. Modul Daya NO. | 3 | 5/6 | 10 | |
INPUT | ||||
Input Utama | Tegangan Nominal (Vac) | 380/400/415 | ||
Range Tegangan (Vac) | 138~485Vac;305~485Vac beban,138~305Vac beban | |||
Urutane | 3-fase ing / 3-fase metu | |||
Frekuensi Nominal (Hz) | 40-70 | |||
Faktor Daya | ≥0.99 | |||
Distorsi Harmonik (THDi) | ≤3% (100% beban) | |||
Bypass Input | Tegangan Nominal (Vac) | 380/400/415 | ||
Range Tegangan (Vac) | 220 Vac:25%(+10%+15%+20%) | |||
230 Vac: 20%(+10%+15%) | ||||
240 Vac: 15%(+10%);-45%(-10%,-20%,-30%) | ||||
Urutane | 3-fase ing / 3-fase metu | |||
Daya Walking In | YA | |||
Bypass Back Irigasi | YA | |||
Akses Generator | YA | |||
OUTPUT | ||||
Tegangan (Vac) | 380/400/415±1% | |||
Faktor daya | 1 | |||
Frekuensi (Hz) | Mode AC | ±1%/±2%/±4%/±5%/±10% | ||
Mode baterei | (50/60±0,1%)Hz | |||
wangun gelombang | Pure Sinewave | |||
Faktor Crest sing bisa ditampa | 3:01 | |||
Distorsi Harmonik (THDV) | ≤2% (100% Beban Linear);≤3% (100% Beban Non-linear) | |||
Wektu Transfer (ms) | 0 | |||
Efisiensi (%) | 95,50% | |||
Kapabilitas Overload | 1 jam kanggo 110%, 10 menit kanggo 125%, 1 menit kanggo 150%, 200ms kanggo> 150% | |||
BATERI | ||||
Arus Pengisian Maksimum (A) | 18 | |||
Tegangan nominal | ±180V/±192V/±204V/±216V/±228V/±240/±252/±264/±276/±288/±300Vdc | |||
(30/32/34/36/38/40/42/44/46/48/50 keping) | ||||
LINGKUNGAN | ||||
Suhu operasi | 0 ℃ ~ 40 ℃ | |||
Suhu panyimpenan | -25 ℃ ~ 55 ℃ | |||
Kelembapan Relatif | 0~95% | |||
Altitude | ||||
Tingkat Kebisingan (dB) | ||||
FISIK | ||||
Ukuran (D x W x H) mm | Kabinet UPS Kab | 600×850×1350 | 600×850×1350 600×850×1550 | 600×850×2000 |
Modul | 440×620×86 | |||
Bobot Net (kg) | Kabinet UPS Kab | 140 | 155/170 | 290 |
Modul | rong puluh siji |