Loj luv nqi 0u Ntsug Rack Intelligent PDU, 1 Theem, Metered-los ntawm-qhov hluav taws xob nrog Switching, 16A, (16) C13 Qhov hluav taws xob-Rpnetv11-16c13
Peb hais kom dhau lub hauv paus ntsiab lus ntawm kev txhim kho ntawm 'High zoo zoo, Ua tau zoo, Lub siab dawb paug thiab Down-rau-lub ntiaj teb ua hauj lwm mus kom ze' kom xa koj nrog cov tuam txhab zoo heev ntawm kev ua rau loj luv nqi 0u Vertical Rack Intelligent PDU, 1 Theem, Metered-by-Outlet Nrog Switching, 16A, (16) C13 Outlet-Rpnetv11-16c13, Peb yuav ua kom muaj zog ntxiv los pab cov neeg yuav khoom hauv tsev thiab thoob ntiaj teb, thiab tsim kom muaj kev sib koom tes thiab kev sib tw yeej-yeej ntawm peb. peb txaus siab tos txais koj txoj kev koom tes ua tsaug.
Peb insist dhau lub hauv paus ntsiab lus ntawm kev txhim kho ntawm 'High zoo zoo, ua tau zoo, Sincerity thiab down-to-earth ua hauj lwm mus kom ze' kom xa koj nrog zoo heev tuam txhab uas muag ntawm kev ua.Tuam Tshoj 0u PDU thiab Fais Fais Distribution Unit , Peb cov khoom muaj npe nrov hauv cov lus, zoo li South American, Africa, Asia thiab lwm yam. Cov tuam txhab tsim "tsim thawj cov khoom lag luam" raws li lub hom phiaj, thiab siv zog los muab cov neeg siv khoom nrog cov khoom zoo, muab cov kev pabcuam zoo tom qab muag thiab kev txhawb nqa, thiab cov neeg siv khoom muaj txiaj ntsig, tsim kom muaj kev ua haujlwm zoo dua thiab yav tom ntej!
Nta
Xaiv lub qhov (socket).
Plug xaiv
Cov txiaj ntsig tseem ceeb
A. Kev tswj xyuas chaw taws teeb
a. Cascade tswj (SNMP V1.V2.V3)
b. Wifi txuas
c. Cov ntaub ntawv graphical zaub d. Kev tswj cov neeg siv
e. Lub cav tau txais kev cawmdim
f. Ntau lub tswb hom g. Kev tswj xyuas kev nkag, los ntawm telnet, ssh lossis modbus-rtu h. Ntau qhov kev xaiv tso zis
B. Saib xyuas muaj nuj nqi
a. Saib xyuas input voltage b. Saib xyuas tag nrho cov load tam sim no
c. Saib xyuas tag nrho lub zog (KW)
d. Saib xyuas kev siv hluav taws xob (KWH)
e. Lub cev muaj zog tag nrho
f. Saib xyuas txhua qhov hluav taws xob hluav taws xob
g. Xam txhua lub zog siv zog
C. Tswj muaj nuj nqi
a. On / off tswj rau txhua qhov hluav taws xob
b. On / off time setting rau txhua qhov hluav taws xob
c. Boot sij hawm ncua sij hawm
d. Teem tam sim no txwv rau txhua qhov hluav taws xob
e. Kev tiv thaiv overload (automatic fais fab tuag)
Daim ntawv thov
Daim ntawv thov: Hnub tim Center, Teeb pom kev zoo Center, Chav Cav, Chaw Nyiaj Txiag, Lub Tsev Kawm Ntawv, Chaw Tsim Khoom, Mining Farm.
Factory Production Line
Ntim
Peb hais kom dhau lub hauv paus ntsiab lus ntawm kev txhim kho ntawm 'High zoo zoo, Ua tau zoo, Lub siab dawb paug thiab Down-rau-lub ntiaj teb ua hauj lwm mus kom ze' kom xa koj nrog cov tuam txhab zoo heev ntawm kev ua rau loj luv nqi 0u Vertical Rack Intelligent PDU, 1 Theem, Metered-by-Outlet Nrog Switching, 16A, (16) C13 Outlet-Rpnetv11-16c13, Peb yuav ua kom muaj zog ntxiv los pab cov neeg yuav khoom hauv tsev thiab thoob ntiaj teb, thiab tsim kom muaj kev sib koom tes thiab kev sib tw yeej-yeej ntawm peb. peb txaus siab tos txais koj txoj kev koom tes ua tsaug.
Kev txo nqi lojTuam Tshoj 0u PDU thiab Fais Fais Distribution Unit , Peb cov khoom muaj npe nrov hauv cov lus, zoo li South American, Africa, Asia thiab lwm yam. Cov tuam txhab tsim "tsim thawj cov khoom lag luam" raws li lub hom phiaj, thiab siv zog los muab cov neeg siv khoom nrog cov khoom zoo, muab cov kev pabcuam zoo tom qab muag thiab kev txhawb nqa, thiab cov neeg siv khoom muaj txiaj ntsig, tsim kom muaj kev ua haujlwm zoo dua thiab yav tom ntej!
Input yam ntxwv | |
Input voltage | 240V Ib Theem (LNG) mus rau 240V Ib Theem |
380V 3Phase (LLLNG) rau 220V Ib Phase | |
415V 3Phase (LLLNG) rau 240V Ib Phase | |
433V 3Phase (LLLNG) rau 250V Ib Phase | |
Input connector | 150Ax5wires (los yog junction box, input breaker yeem) |
zaus | 50/60Hz |
Tag nrho tam sim no | Max 125A |
Rating tso zis Voltage | 208-300VAC |
Max tso zis zog rau txhua qhov hluav taws xob | Nyob rau hauv 208V, Max 3328W ib qhov hluav taws xob |
Nyob rau hauv 240V, Max 3840W ib qhov hluav taws xob | |
Nyob rau hauv 250V, Max 4000W ib qhov hluav taws xob | |
Tag nrho cov zis zog | Luas 4432 Wx 24 |
Qhov (socket) Standard | 12pcs C19 (Customized) |
Chaw taws teeb tswj | TCP / IP, Kub-swap tswj ntsuas ntsuas |
Breaker | 125A 3P breaker nrog UL lossis CE |
Hlau specification | UL ntawv pov thawj, nrog nplaim retardant muaj nuj nqi |
Cov khoom kuaj | |
Hi-pot test | PASS |
Ntsej Tsuag Test | PASS |
Kev xeem av | PASS |
Polarity Test | PASS |
IR Test | PASS |
Socket Life Test | PASS |
Kev kuaj kev laus | PASS |
Khoom xim & khoom siv | |
Khoom xim | Nyiaj dawb los yog dub |
Yas nplaim retardant ntsuas | UL94V-0 qib |