China factory IP20 Online modular UPS 3 Phase for Internet Data Center 20kva 100kva 300Kva
Bayani
Marka: Banatton
Wurin asali: China
Nau'in: UPS na kan layi
Lambar Samfura: BNT9300-M 20 ~ 300KVA
Mataki: Mataki Uku
Waveform: Tsaftataccen igiyar ruwa
Lokacin canja wuri: 0ms
Matsakaicin ƙarfi: 0.9
Yawan aiki: 20KVA-300KVA
Kariya: gajeriyar kewayawa, sama da ƙarfin lantarki, kariyar haɗin kai
OEM/ODM: Iya
Ikon bayarwa: 5000 Piece/ Pieces per month
Marufi: Kunshin kwali ko katako ko kamar yadda kuka nema
Siffofin
Take: Ƙarfin Ƙarfafawa da Tsaro: Binciken Fa'idodinUPS na ModularTsarukan aiki
A cikin duniya mai saurin tafiya da fasaha a yau, buƙatun samar da wutar lantarki mai dogaro da ƙarfi ya zama mafi mahimmanci fiye da kowane lokaci. Kasuwanci da masana'antu sun dogara kacokan akan samar da wutar lantarki mara yankewa don ci gaba da gudanar da ayyuka cikin kwanciyar hankali. Wannan shi ne inda tsarin UPS na zamani (Uninterruptible Power Supply) ya shigo cikin wasa, yana ba da mafita mai ƙarfi don tabbatar da kwanciyar hankali da tsaro.
Tsarukan UPS na Modular, kamar matakai uku200KVA UPS , an tsara su don samar da ƙarfi da aminci don aikace-aikace iri-iri. Waɗannan tsarin suna sanye take da sifofi masu ci gaba waɗanda ke ba su damar iya sarrafa abubuwan da suka fi yawa da gajerun kewayawa, suna ba da ƙarin kariya ga kayan aiki masu mahimmanci da injuna. Wannan fasalin yana da mahimmanci musamman a wuraren da ake yawan samun canjin wutar lantarki da hargitsin lantarki, saboda yana taimakawa hana yuwuwar lalacewa da raguwar lokaci.
Ɗaya daga cikin manyan fa'idodin tsarin UPS na zamani shine ikon su don daidaitawa da canza buƙatun wutar lantarki. Tare da ƙirar ƙira, waɗannan tsarin UPS za a iya faɗaɗa su cikin sauƙi ko faɗaɗa don saduwa da buƙatun ƙarfin girma, yana mai da su mafita mai sassauƙa kuma mai tsada ga kasuwancin kowane girma. Wannan sikelin kuma yana tabbatar da cewa ƙarfin ya kasance mai ƙarfi kuma abin dogaro ko da lokacin da kaya ke ƙaruwa, yana ba da kwanciyar hankali ga kasuwancin da ke buƙatar ci gaba, ƙarfi mara yankewa.
Bugu da ƙari, ƙaƙƙarfan ƙira na tsarin UPS na zamani yana sa su dace da jure matsanancin yanayi. Ko zafi, zafi ko wasu abubuwan muhalli, waɗannan tsarin UPS an ƙera su ne don kiyaye kwanciyar hankali da aminci, tabbatar da mahimman tsarin suna ci gaba da aiki koda ƙarƙashin yanayi masu wahala.
A taƙaice, tsarin UPS na zamani yana ba da mafita mai gamsarwa ga kasuwanci da masana'antu waɗanda ke neman haɓaka kayan aikin wutar lantarki. Waɗannan tsarin suna da keɓantaccen ikon ɗaukar nauyi mai yawa, daidaitawa da canza buƙatun wutar lantarki da jure matsanancin yanayi, samar da abin dogaro, amintaccen ƙarfi wanda ke da mahimmanci ga ingantaccen aiki na kayan aiki da injina. Zuba jari a cikin tsarin UPS na zamani ba kawai don tabbatar da samar da wutar lantarki ba ne kawai, amma har ma don tabbatar da kwanciyar hankali da amincin tsarin duka.
Karamin Bayani
1. A cikin lokacin garanti injin yana da matsala, tuntuɓi ma'aikatan tallace-tallace, za mu kasance da alhakin sabis na abokin ciniki.
2. Ya wuce lokacin garanti, aiki mara kyau da lalacewa ta mutum, har yanzu za mu ba da taimako da tallafi, za mu samar da kayan aiki a farashin farashi.
3. Bisa ga bukatun abokin ciniki, za mu iya samar da rashin daidaituwa, amma farashin zai iya zama dan kadan fiye da na'ura na gargajiya.
Aikace-aikace
Cibiyar sarrafa bayanai, The host system, Computer server, Medical, Traffic, Electricity, IT, Industrial da sauran masana'antu.
Layin Samar da Masana'antu
Marufi
MISALI | BNT990-M | BNT9150/180-M | BNT9300-M | |
Ƙarfin Ƙarfi | Ƙarfin Majalisar | 20-90kVA / 20-90kW | 25-150kVA / 25-150kW 30-180kVA / 30-180kW | 30-300kVA / 30-300kW |
Ƙarfin Module PPwer ɗaya | 20kVA / 20kW, 25kVA / 25kW, 30kVA / 30kW | |||
MAX. Module Power NO. | 3 | 5/6 | 10 | |
INPUT | ||||
Babban shigarwar | Nau'in Wutar Lantarki (Vac) | 380/400/415 | ||
Wutar Lantarki (Vac) | 138 ~ 485Vac; 305 ~ 485Vac lodi, 138 ~ 305Vac lodi | |||
Mataki | 3-phase in / 3-phase out | |||
Mitar Suna (Hz) | 40-70 | |||
Factor Power | ≥0.99 | |||
Harmonic Distortion (THDi) | ≤3% (100% kaya) | |||
Ketare Shigar | Nau'in Wutar Lantarki (Vac) | 380/400/415 | ||
Wutar Lantarki (Vac) | 220Vac:25%(+10%+15%+20%) | |||
230 Wuta: 20% (+ 10% + 15%) | ||||
240 Wuta: 15% (+10%); -45% (-10%, -20%, -30%) | ||||
Mataki | 3-phase in / 3-phase out | |||
Wutar Wuta a ciki | EE | |||
Kewaya Baya Ban ruwa | EE | |||
Shigar Generator | EE | |||
FITARWA | ||||
Voltage (Vac) | 380/400/415± 1% | |||
Halin wutar lantarki | 1 | |||
Mitar (Hz) | Yanayin AC | ± 1% / ± 2% / 4% / ± 5% / ± 10% | ||
Yanayin baturi | (50/60±0.1%)Hz | |||
Waveform | Tsabtace Sinewave | |||
Factor Crest Mai Amincewa | 3:01 | |||
Harmonic Distortion(THDV) | ≤2% (100% Load Load); ≤3% (100% Load ɗin da ba na layi ba) | |||
Lokacin Canjawa (ms) | 0 | |||
inganci(%) | 95.50% | |||
Iyawa mai yawa | 1 hour don 110%, 10mins don 125%, 1 min don 150%, 200ms don> 150% | |||
BATURE | ||||
Matsakaicin Cajin Yanzu (A) | 18 | |||
Wutar Wutar Lantarki | ± 180V / ± 192V / 204V / 216V / ± 228V / 240 / ± 252 / ± 264 / ± 276 / ± 288 / ± 300Vdc | |||
(30/32/34/36/38/40/42/44/46/48/50 inji mai kwakwalwa) | ||||
Muhalli | ||||
Yanayin Aiki | 0 ℃ ~ 40 ℃ | |||
Ajiya Zazzabi | -25 ℃ ~ 55 ℃ | |||
Danshi mai Dangi | 0 ~ 95% | |||
Tsayi | ||||
Matsayin Amo (dB) | ||||
NA JIKI | ||||
Girma (D x W x H) mm | UPS Majalisar | 600×850×1350 | 600×850×1350 600×850×1550 | 600×850×2000 |
Module | 440×620×86 | |||
Net Weight(kg) | UPS Majalisar | 140 | 155/170 | 290 |
Module | ashirin da daya |